Subdivision

Concept Plan

9-SJ-06-C

Recommended for approval
by the Planning Commission

APPROVE variances 1-2 because of site constraints
APPROVE a variance of right-of-way dedication from 44' to 35' from the centerline of Gleason Dr.

APPROVE the concept plan subject to 9 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (91-1-102)
3. Meeting all applicable requirements of the Knox County Dept. of Engineering and Public Works
4. Placing a note on the final plat that all lots will have access to the internal street system only
5. Placing a note on the plan that the proposed road is to a private joint permanent easement
6. Certification on the final plat by the applicant's surveyor that there is adequate sight distance to meet the requirement Section 62-88 of the Subdivision Regulations
7. Prior to certification of the final plat for the subdivision, establishing a homeowners association for the purpose of maintaining the storm water drainage system.
8. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff
9. Meeting all requirements of the approved use on review development plan

Applicant Request

+
Subdivision
Gleason Court
Lots
17 (Split)
Proposed Density
5.97 du/ac
Residential?
Yes - SF

Variances

1. Vertical curve variance from 197' to 127' at sta. 1+76 of proposed road.
2.. Intersection separation variance from Pickett Place Wy. and Ashton Ct.
3. Right-of-way dedication from 44' to 25' from the centerline of Gleason Dr.


Property Information

+
Location
North side of Gleason Dr., west side of Pickett Place Wy.

Commission District 5


Size
2.85 acres

Sector
Southwest County

Currently on the Property
Vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1-2 because of site constraints
APPROVE a variance of right-of-way dedication from 44' to 35' from the centerline of Gleason Dr.

APPROVE the concept plan subject to 9 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (91-1-102)
3. Meeting all applicable requirements of the Knox County Dept. of Engineering and Public Works
4. Placing a note on the final plat that all lots will have access to the internal street system only
5. Placing a note on the plan that the proposed road is to a private joint permanent easement
6. Certification on the final plat by the applicant's surveyor that there is adequate sight distance to meet the requirement Section 62-88 of the Subdivision Regulations
7. Prior to certification of the final plat for the subdivision, establishing a homeowners association for the purpose of maintaining the storm water drainage system.
8. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff
9. Meeting all requirements of the approved use on review development plan
Disposition Summary
APPROVE variances 1-2 because of site constraints
APPROVE a variance of right-of-way dedication from 44' to 35' from the centerline of Gleason Dr.

APPROVE the concept plan subject to 9 conditions

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (91-1-102)
3. Meeting all applicable requirements of the Knox County Dept. of Engineering and Public Works
4. Placing a note on the final plat that all lots will have access to the internal street system only
5. Placing a note on the plan that the proposed road is to a private joint permanent easement
6. Certification on the final plat by the applicant's surveyor that there is adequate sight distance to meet the requirement Section 62-88 of the Subdivision Regulations
7. Prior to certification of the final plat for the subdivision, establishing a homeowners association for the purpose of maintaining the storm water drainage system.
8. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff
9. Meeting all requirements of the approved use on review development plan

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Gleason Court

Jim Sullivan


Case History