Details of Action
−
+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names that are consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. Compaction of fill areas to be done in accordance with the requirements of the Knox County Dept. of Engineering and Public Works.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Provision of separate right and left turn lanes On Madison Av. at the intersection with E. Governor John Sevier Hwy.
6. Placing the note on the concept and development plans dealing with construction within the depressed area on the final plat. MPC staff reserves the right to recommend changes to the text of this note prior to final plat approval.
7. Soil testing, by a qualified geotechnical engineer, of each proposed building site that is located within 50' of the depressed area
8. Review and approval of each building permit for dwellings to be located within 50' of the depressed area by the Knox County Dept. of Engineering and Public Works
9. Provision of 300' of sight distance at each proposed driveway entrance
10. Provision of sight distance easements as required by the Knox County Dept. of Engineering and Public Works
11. Meeting all applicable requirements and obtaining all required permits from the Tennessee Dept. of Environment and Conservation and the Tenn. Valley Authority
12. All sidewalks are to be constructed as shown on the development plan. All sidewalk construction must be ADA compliant
13. Obtaining a Tenn. Dept. of Transportation entrance permit
14. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Property Information
−
+
LocationWest side of E. Gov. John Sevier Hwy., south of Holbert Ln.
Commission District 8
Size33.02 acres
Sector
Currently on the Property
Vacant land
Growth PlanPlanned Growth Area
- Utilities
ElectricityKnoxville Utilities Board
Natuarl GasKnoxville Utilities Board
SewerKnoxville Utilities Board
TelephoneMetro Group Bell South Telephone
WaterKnoxville Utilities Board
Case Notes
−
+
Staff Recommendation
APPROVE variances 1-4 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard.
APPROVE the concept plan subject to 14 conditions
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names that are consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. Compaction of fill areas to be done in accordance with the requirements of the Knox County Dept. of Engineering and Public Works.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Provision of separate right and left turn lanes On Madison Av. at the intersection with E. Governor John Sevier Hwy.
6. Placing the note on the concept and development plans dealing with construction within the depressed area on the final plat. MPC staff reserves the right to recommend changes to the text of this note prior to final plat approval.
7. Soil testing, by a qualified geotechnical engineer, of each proposed building site that is located within 50' of the depressed area
8. Review and approval of each building permit for dwellings to be located within 50' of the depressed area by the Knox County Dept. of Engineering and Public Works
9. Provision of 300' of sight distance at each proposed driveway entrance
10. Provision of sight distance easements as required by the Knox County Dept. of Engineering and Public Works
11. Meeting all applicable requirements and obtaining all required permits from the Tennessee Dept. of Environment and Conservation and the Tenn. Valley Authority
12. All sidewalks are to be constructed as shown on the development plan. All sidewalk construction must be ADA compliant
13. Obtaining a Tenn. Dept. of Transportation entrance permit
14. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1-4 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard.
APPROVE the concept plan subject to 14 conditions
Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names that are consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. Compaction of fill areas to be done in accordance with the requirements of the Knox County Dept. of Engineering and Public Works.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Provision of separate right and left turn lanes On Madison Av. at the intersection with E. Governor John Sevier Hwy.
6. Placing the note on the concept and development plans dealing with construction within the depressed area on the final plat. MPC staff reserves the right to recommend changes to the text of this note prior to final plat approval.
7. Soil testing, by a qualified geotechnical engineer, of each proposed building site that is located within 50' of the depressed area
8. Review and approval of each building permit for dwellings to be located within 50' of the depressed area by the Knox County Dept. of Engineering and Public Works
9. Provision of 300' of sight distance at each proposed driveway entrance
10. Provision of sight distance easements as required by the Knox County Dept. of Engineering and Public Works
11. Meeting all applicable requirements and obtaining all required permits from the Tennessee Dept. of Environment and Conservation and the Tenn. Valley Authority
12. All sidewalks are to be constructed as shown on the development plan. All sidewalk construction must be ADA compliant
13. Obtaining a Tenn. Dept. of Transportation entrance permit