Subdivision

Concept Plan

9-SE-04-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 - 6 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 8 conditions:


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Meeting all applicable requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Prior to final plat approval, performing the necessary grading and improvements within the Choto Road right-of-way (subject to approval of Knox County Department of Engineering and Public Works) to obtain the require 300' of sight distance in both directions along Choto Rd. at the proposed entrance to the subdivision and certifying on the final plat that the required sight distance exists.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5 Place a note on the final plat that all lots will have access only to the internal street system.
6. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the joint permanent easement, common area, amenities and drainage system.
7. Meeting all requirements of the approved use on review development plan.
8. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

Applicant Request

+
Subdivision
Kennesaw Park
Lots
20 (Split)
Proposed Density
0.996 du/ac

Variances

1. Horizontal curve variance on Road A at station 0+93.74, from 250' to 100'.
2. Horizontal curve variance on Road A at station 4+30.89, from 250' to 100'.
3. Horizontal curve variance on Road A at station 6+70.58, from 250' to 100'.
4. Horizontal curve variance on Road A at station 13+49.22, from 250' to 100'.
5. Vertical curve variance on Road A at station 0+75.49, from 135' to 126'.
6. Vertical curve variance on Road A at station 13+86.27, from 237.5' to 215'.


Property Information

+
Location
Southeast side of Choto Rd., southwest side of Whitten Ln.

Commission District 5


Size
20.08 acres

Sector
Southwest County

Currently on the Property
Vacant land

Growth Plan
Rural Area

Case Notes

+
Staff Recommendation
APPROVE variances 1 - 6 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 8 conditions:

1. Meeting all applicable requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Prior to final plat approval, performing the necessary grading and improvements within the Choto Road right-of-way (subject to approval of Knox County Department of Engineering and Public Works) to obtain the require 300' of sight distance in both directions along Choto Rd. at the proposed entrance to the subdivision and certifying on the final plat that the required sight distance exists.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5 Place a note on the final plat that all lots will have access only to the internal street system.
6. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the joint permanent easement, common area, amenities and drainage system.
7. Meeting all requirements of the approved use on review development plan.
8. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1 - 6 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 8 conditions:

Details of Action
1. Meeting all applicable requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Prior to final plat approval, performing the necessary grading and improvements within the Choto Road right-of-way (subject to approval of Knox County Department of Engineering and Public Works) to obtain the require 300' of sight distance in both directions along Choto Rd. at the proposed entrance to the subdivision and certifying on the final plat that the required sight distance exists.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5 Place a note on the final plat that all lots will have access only to the internal street system.
6. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for maintenance of the joint permanent easement, common area, amenities and drainage system.
7. Meeting all requirements of the approved use on review development plan.
8. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Kennesaw Park

Forest Brook Development, LLC


Case History