Subdivision

Concept Plan

8-SC-09-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 & 2 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
DENY variance 3

APPROVE the concept plan subject to 9 conditions


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Woodson Trail
Lots
41 (Split)
Proposed Density
3.08 du/ac
Residential?
Yes - SF

Variances

1. Vertical curve length from 268.75' to 161.19' at sta 2+04.61 of Briar Rock Ln.
2. Vertical curve length from 215' to 165' at sta 4+78 of Briar Rock Ln.
3. Vertical curve length from 164.4' to 109.6' at sta 1+77 of Chimney Rock Ln.


Property Information

+
Location
Southeast side of Woodson Trail, northeast of Spring Creek Rd.

Council District 1


Size
23.11 acres

Sector
South County

Currently on the Property
Partially developed subdivision

Growth Plan
Urban Growth Area (Inside City Limits)

Case Notes

+
Staff Recommendation
APPROVE variances 1 & 2 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
DENY variance 3

APPROVE the concept plan subject to 9 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System within Knoxville (City Ord. 0-280-90).
3. Compaction of fill areas to be done in accordance with the requirements of the Knoxville Engineering Dept..
4. Meeting all applicable requirements of the Knoxville Department of Engineering.
5. Correct the grade at intersection of Chimney Rock Ln. and Briar Rock Ln. to not exceed 3% and provide a vertical curve with a K value of not less than 15 at sta 1+77 of Chimney Rock Ln.
6. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation
7. Meeting all requirements of the previously approved Use-on-Review development plan (1-E-07-UR)
8. Sewer connections must be approved through KUB's sewer capacity reservation program prior to final plat approval
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1 & 2 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
DENY variance 3

APPROVE the concept plan subject to 9 conditions

What's next?

+
After the Planning Commission
Because of its location in the City, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Woodson Trail

R.W Graf, Inc.


Case History