Subdivision

Concept Plan

8-SB-13-C

Recommended for approval
by the Planning Commission

APPROVE variances 1-3 because the site's topography and location restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 10 conditions


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Maitland Woods, Phase III
Lots
9 (Split)
Proposed Density
.33 du/ac
Residential?
Yes - SF

Variances

1. Vertical curve variance from 240' to78' at sta. 0+39 & from 343' to 286' at sta. 4+33 of JPE #1
2. Variance of road grade from 12% to 15% from sta. 0+78 to 3+10 of JPE #1
3. Variance of required property line and pavement radius from 25' to 0' at the intersection of Ancient Oak Ln. and JPE #1


Property Information

+
Location
Northeast end of Ancient Oak Ln., northeast of Sands Rd.

Commission District 3
Census Tract 46.05


Size
28.59 acres

Sector
Northwest County

Currently on the Property
Partially developed subdivision

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1-3 because the site's topography and location restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 10 conditions

1. Meeting all relevant requirements of the Knox County Health Department.
2. Provision of street names for JPE #1 and JPE #2 which are consistent with the Uniform Street Naming and Addressing System within Knox County (91-1-102).
3. Meeting all applicable requirements of the Knox County Dept. of Engineering and Public Works
4. Meeting all requirements and obtaining any/all required permits from the Tenn. Dept. of Environment and Conservation
5. Prior to certification of the final plat for the subdivision, establishing a homeowners association for the purpose of maintaining the stormwater drainage system.
6. Prior to final plat approval, obtain an off-site drainage easement if required by the Knox County Dept. of Engineering and Public Works
7. Closure of that portion of Altacrest Ln. that has been dedicated as a public right-of-way or construct a cul de sac to terminate the public portion of that street
8. Provide a typical cross section for the proposed JPE's. Public road standards will be required excluding the pavement width. Curbs will be required for JPE#1
9. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff
10. Meeting all requirements of the approved use on review development plan
Disposition Summary
APPROVE variances 1-3 because the site's topography and location restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 10 conditions

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Maitland Woods, Phase III

GRAD Land Development


Case History