Subdivision

Concept Plan

5-SD-02-C

Recommended for approval
by the Planning Commission

APPROVE variance 1- 4 due to topography, and the proposed variances will not create a traffic hazard
APPROVE the concept plan subject to 10 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville (Ord. O-280-90).
3. Final approval of the rezoning of this site to RP-1 at a density of 5.60 du/ac or greater by the Knoxville City Council.
4. Prior to commencing any grading on this site provide written confirmation from Colonial Pipeline Company that they have reviewed and approved the grading plan for this project.
5. The retaining wall shown along the northern boundary of the site being designed by a structural engineer.
6. Obtaining a street connection permit from the Tenn. Dept. of Transportation.
7. Construction of the right turn deceleration lane as called for in the traffic impact study if required of the Tenn. Dept. of Transportation.
8. Meeting all applicable requirements of the Knoxville City engineer.
9. Meeting all requirements of the approved use on review.
10. A final plat based on this concept plan will not accepted for review until certification of design plan has been submitted to MPC staff.

Applicant Request

+
Subdivision
MPM Development on Middlebrook Pike
Lots
145 (Split)
Proposed Density
5.60 du/ac

Variances

1. Intersection grade variance from 1% to 3% on Road A at Middlebrook Pk.
2. Vertical curve variance from 201.5' to 170' at sta. 1+25 od Road A.
3. Horizontal curve variance from 250' to 100' at sta. 11+50 of Road D.
4. Right-of-way dedication on Middlebrook Pk. From 56' to 51' from the center line.


Property Information

+
Location
North side of Middlebrook Pk., east of West Forest Bv.

Council District 3


Size
25.89 acres

Sector
Northwest City

Currently on the Property
Three single family dwellings and vacant land

Growth Plan
Urban Growth Area (Inside City Limits)

Case Notes

+
Staff Recommendation
APPROVE variance 1- 4 due to topography, and the proposed variances will not create a traffic hazard

APPROVE the concept plan subject to 10 conditions

1. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville (Ord. O-280-90).
3. Final approval of the rezoning of this site to RP-1 at a density of 5.60 du/ac or greater by the Knoxville City Council.
4. Prior to commencing any grading on this site provide written confirmation from Colonial Pipeline Company that they have reviewed and approved the grading plan for this project.
5. The retaining wall shown along the northern boundary of the site being designed by a structural engineer.
6. Obtaining a street connection permit from the Tenn. Dept. of Transportation.
7. Construction of the right turn deceleration lane as called for in the traffic impact study if required of the Tenn. Dept. of Transportation.
8. Meeting all applicable requirements of the Knoxville City engineer.
9. Meeting all requirements of the approved use on review.
10. A final plat based on this concept plan will not accepted for review until certification of design plan has been submitted to MPC staff.
Disposition Summary
APPROVE variance 1- 4 due to topography, and the proposed variances will not create a traffic hazard
APPROVE the concept plan subject to 10 conditions

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville (Ord. O-280-90).
3. Final approval of the rezoning of this site to RP-1 at a density of 5.60 du/ac or greater by the Knoxville City Council.
4. Prior to commencing any grading on this site provide written confirmation from Colonial Pipeline Company that they have reviewed and approved the grading plan for this project.
5. The retaining wall shown along the northern boundary of the site being designed by a structural engineer.
6. Obtaining a street connection permit from the Tenn. Dept. of Transportation.
7. Construction of the right turn deceleration lane as called for in the traffic impact study if required of the Tenn. Dept. of Transportation.
8. Meeting all applicable requirements of the Knoxville City engineer.
9. Meeting all requirements of the approved use on review.
10. A final plat based on this concept plan will not accepted for review until certification of design plan has been submitted to MPC staff.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

MPM Development on Middlebrook Pike

MPM Development Co., LLC


Case History