Subdivision

Concept Plan

4-SE-24-C

Approved with conditions
by the Planning Commission

Approve the requested variance to reduce the minimum broken back curve tangent on Road 'C' at STA 8+32.70 from 150 ft to 140.63 ft, based on the following evidence of hardship presented by the applicant.
a. The reduced tangent will help limit disturban


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Prices Point
Lots
145 (Split)
Proposed Density
4.0 du/ac

Variances

VARIANCES
1) Reduce the minimum intersection separation along E. Governor John Sevier Highway, between the centerlines of Road 'A' and French Road, from 400 ft to 265 ft.
2) Reduce the minimum broken back curve tangent on Road 'C' at STA 8+32.70 from 150 ft to 140.63 ft.
3) Reduce the minimum broken back curve tangent on Road 'D' at STA 6+45.35 from 150 ft to 88.41 ft.

ALTERNATIVE DESIGN STANDARDS REQUIRING KNOXVILLE-KNOX COUNTY PLANNING COMMISSION APPROVAL
1) Reduce the minimum horizontal curve radius on Road 'B' at STA 5+60 from 250 ft to 100 ft.
2) Reduce the minimum horizontal curve radius on Road 'C' at STA 9+73 from 250 ft to 100 ft.
3) Reduce the minimum horizontal curve radius on Road 'D' at STA 7+33 from 250 ft to 150 ft.
4) Reduce the minimum horizontal curve radius on Road 'D' at STA 13+46 from 250 ft to 100 ft.


Property Information

+
Location
0 E GOVERNOR JOHN SEVIER HWY

West side of E. Governor John Sevier Hwy, west of French Rd

Commission District 9


Size
36.87 acres

Sector
South County

Land Use Designation? LDR (Low Density Residential), HP (Hillside Protection), SP (Stream Protection)


Currently on the Property
Agriculture/Forestry/Vacant Land, Water

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
Approve the requested variance to reduce the minimum broken back curve tangent on Road 'C' at STA 8+32.70 from 150 ft to 140.63 ft, based on the following evidence of hardship presented by the applicant.
a. The reduced tangent will help limit disturban

1. Connection to sanitary sewer and meeting any other relevant requirements of the utility provider.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (County Ord. 91-1-102).
3. Implementing the recommendations of the Heartland Development (Prices Point) Subdivision Transportation Impact Study (AJAX Engineering, 3/27/2024) per the requirements of Knox County Engineering and Public Works and TDOT during the design plan phase. See Exhibits for the conclusions and recommendations of the TIS.
4. A Memorandum of Understanding with Knox County Engineering and Public Works is required per Chapter 54, Article V of the Knox County Code (Ord. O-23-4-102) for road improvements within existing public rights-of-way.
5. Providing the property line radii at the corner of the Road 'A' and E. Governor John Sevier Highway intersection per Section 3.04.J.2. of the Subdivision Regulations.
6. Providing a 50-ft landscape buffer along the E. Governor John Sevier Highway frontage per the condition of zoning. During the design plan phase, a landscape plan must be submitted to Planning staff to confirm compliance with the recommendations of the Governor John Sevier Scenic Highway Corridor Study. The landscaping shall include a variety of deciduous and evergreen trees and shrubs to create a visual screen. The planting must be placed within the 50-ft buffer but does not have to fill the entire 50-ft depth. Plantings must be located outside any required sight distance triangles.
7. Installing notification of future street connection at the northeast terminus of Road 'D' as required by Section 3.04.C.2.d. of the Subdivision Regulations.
8. Providing a temporary turnaround at the northeast terminus of Road 'D' per the requirements of Knox County Engineering and Public Works during the design plan phase.
9. Providing a stream determination study to Knox County Engineering and Public Works during the design plan phase. If there is a stream, the required buffers must be provided on the final plat. Residential lots that do not have buildable areas outside the stream buffer must be consolidated with other lots.
10. Proving 200-ft sight distance easements through curves with a horizontal radius of less than 200 ft. Driveways must have a depth of 20 ft past the sight distance easement.
11. Meeting all other applicable requirements of the Knox County Department of Engineering and Public Works.
12. Place a note on the final plat that all lots will have access only to the internal street system.
13. Before certification of the final plat for the subdivision, establish a property owners association or other legal entity responsible for maintaining common facilities, such as common areas, amenities, private roads, and/or stormwater drainage systems.
Disposition Summary
Approve the requested variance to reduce the minimum broken back curve tangent on Road 'C' at STA 8+32.70 from 150 ft to 140.63 ft, based on the following evidence of hardship presented by the applicant.
a. The reduced tangent will help limit disturban

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Prices Point

Heartland Development, LLC


Case History