Historic Zoning Commission

Edgewood-Park City H-1: Level I/II

4-L-08-HZ

Staff Recommendation

APPROVE Certificate No. 040108EDG. Work proposed in Level II is consistent with approved Design guidelines; Level I certificate was issued 4/2/08.


Applicant Request

Level II. Replacement/repair (and Level I: Standard Repair)

Level I: Repair windows as necessary; install imbricated shingles on gable ends; repair siding, corner boards, and skirt boards as necessary; install 8" square wood columns with brackets on front porch, and balustrade of 2x2's on 4-5" centers set into top and bottom rails; install adequate foundation on rear addition, bricked on exterior; repair existing foundation parge coat; install half view wood door; install color clad storm windows; repair or install gutters; repair or install new color-clad storm windows; reroof, replacing asphalt shingles with like materials and repairing roof deck if needed. (Issued 4/1/2008)
Level II: Remove unoriginal kitchen window on east side addition; remove rear bathroom window on first floor; install skylight on rear, west side, not visible from Jefferson (hidden by dormer); construct square 6x6 porch columns with sawn wood railing with balussters set into top and bottom rails, and brackets surround columns to match brackets on house; construct garage at rear of lot, with garage door access from alley and front entrance with small porch, roof slope at 6/12 or dimension to match house.


Site Info

Bungalow with Craftsman influence (c.1910)

Two story frame with weatherboard siding. Gable roof with side shed dormers and asphalt shingle covering. One story full front porch with concrete floor, replacement metal columns. Three over one and one over one double hung windows, with paired casements on second story front elevation. Interior central brick chimney. Brick foundation. Rectangular plan.


Applicant proposes to remove two windows, one on the rear elevation and one unoriginal window on an addition at the rear of the building; neither window is readily visible from the street, with the only original window being completely hidden on the rear elevation. Both are desirable to increase the efficiency of the interior floor plan. (See Windows, pg. 15, Design Guidelines)
Proposed skylight is at the rear of the side roof elevation, behind a larger dormer, and will not be visible from Jefferson, meeting the design guidelines provisions (see Roofs, Pg. 15, #5.)

Applicant

Jason Canada


Location Knoxville
2032 Jefferson Ave

Owner
Jason Canada