Subdivision

Concept Plan

3-SG-06-C

Approved
by the Planning Commission

APPROVE variances 1-6 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 8 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting all other applicable requirements of the Knox County Health Department.
2. Provision of a street name that is consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. At the design plan stage of the subdivision, providing a detailed grading plan for the building sites on each lot on the hill up to Station 12+00 including identification and design details of any retaining walls.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Certification on the final plat by the applicant's surveyor that there is 300' of sight distance in both directions on Snyder Rd. from the proposed entrance road.
6. Including the sight distance easement across Lot 56 on the final plat.
7. Meeting all requirements of the approved use on review development plan.
8. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff.

Applicant Request

+
Subdivision
Robbins Ridge
Lots
60 (Combine)
Proposed Density
2.45 du/ac
Residential?
Yes - SF

Variances

1. Horizontal curve variance on Robbins Ridge Road at STA 0+66 from 250? to 100?.
2. Horizontal curve variance on Robbins Ridge Road at STA 4+29 from 250? to 200?.
3. Horizontal curve variance on Robbins Ridge Road at STA 8+10 from 250? to 150?.
4. Horizontal curve variance on Robbins Ridge Road at STA 10+17 from 250? to 150?.
5. Broken back curve tangent variance on Robbins Ridge Road between STA 9+58 and 8+69 from 150? to 89?.
6. Maximum street grade variance on Robbins Ridge Road between STA 3+00 and 10+70 from 12% to 13.17%.


Property Information

+
Location
Northwest side of Snyder Rd. at the north end of Clover Fields Ln.

Commission District 5


Size
24.44 acres

Sector
Northwest County

Currently on the Property
Vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1-6 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 8 conditions

1. Connection to sanitary sewer and meeting all other applicable requirements of the Knox County Health Department.
2. Provision of a street name that is consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. At the design plan stage of the subdivision, providing a detailed grading plan for the building sites on each lot on the hill up to Station 12+00 including identification and design details of any retaining walls.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Certification on the final plat by the applicant's surveyor that there is 300' of sight distance in both directions on Snyder Rd. from the proposed entrance road.
6. Including the sight distance easement across Lot 56 on the final plat.
7. Meeting all requirements of the approved use on review development plan.
8. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff.
Disposition Summary
APPROVE variances 1-6 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the concept plan subject to 8 conditions

Details of Action
1. Connection to sanitary sewer and meeting all other applicable requirements of the Knox County Health Department.
2. Provision of a street name that is consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
3. At the design plan stage of the subdivision, providing a detailed grading plan for the building sites on each lot on the hill up to Station 12+00 including identification and design details of any retaining walls.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Certification on the final plat by the applicant's surveyor that there is 300' of sight distance in both directions on Snyder Rd. from the proposed entrance road.
6. Including the sight distance easement across Lot 56 on the final plat.
7. Meeting all requirements of the approved use on review development plan.
8. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Robbins Ridge

Fred Long Construction Concepts


Case History