Subdivision

Concept Plan

3-SG-05-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 - 12 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
APPROVE the Concept Plan subject to 9 conditions:


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County, Ord. 91-1-102.
3. Providing drainage detention at the southwest corner of the property near Reagan Rd., or obtaining an off-site drainage easement at that location. Details to be worked out at the design plan stage of the subdivision.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Placing a note on the final plat that all lots will have access only to the internal street system.
6. Certification on the final plat by the applicant's surveyor that there is 300 feet of sight distance in both directions along Reagan Rd. at both entrances.
7. As a part of the final plat approval, record line of sight easements across the lots that are determined by the Knox County Department of Engineering and Public Works as needing sight distance easements for the curves in the interior streets .
8. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
9. Meeting all requirements of the approved use on review development plan.

Applicant Request

+
Subdivision
Reagan Landing
Lots
136 (Split)
Proposed Density
3.21 du/ac

Variances

1. Horizontal curve variance on Road B at station 1+50, from 250? to 150?.
2. Horizontal curve variance on Road B at station 5+50.94, from 250? to 150?.
3. Horizontal curve variance on Road B at station 4+86.15, from 250? to 125?.
4. Horizontal curve variance on Road B at station 18+66.74, from 250? to 125?.
5. Horizontal curve variance on Road C at station 13+05.40, from 250? to 150?.
6. Horizontal curve variance on Road C at station 21+22.27, from 250? to 125?.
7. Broken back curve tangent variance on Road C at station 21+22.27, from 150? to 109?.
8. Reverse curve tangent variance on Road E at station 2+20.46, from 50? to 0?.
9. Vertical curve variance on Road A at station 1+88.57 from 93.25? to 56?.
10. Vertical curve variance on Road B at station 2+75.66 from 300? to 240?.
11. Vertical curve variance on Road D at station 3+79.68 from 448.5? to 360?.
12. Vertical curve variance on Road G at station 0+60.27 from 105? to 80?.


Property Information

+
Location
East side of Reagan Rd., south of Coward Mill Rd.

Commission District 6


Size
45.50 acres

Sector
Northwest County

Currently on the Property
Residence and vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1 - 12 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 9 conditions:

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County, Ord. 91-1-102.
3. Providing drainage detention at the southwest corner of the property near Reagan Rd., or obtaining an off-site drainage easement at that location. Details to be worked out at the design plan stage of the subdivision.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Placing a note on the final plat that all lots will have access only to the internal street system.
6. Certification on the final plat by the applicant's surveyor that there is 300 feet of sight distance in both directions along Reagan Rd. at both entrances.
7. As a part of the final plat approval, record line of sight easements across the lots that are determined by the Knox County Department of Engineering and Public Works as needing sight distance easements for the curves in the interior streets .
8. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
9. Meeting all requirements of the approved use on review development plan.
Disposition Summary
APPROVE variances 1 - 12 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
APPROVE the Concept Plan subject to 9 conditions:

Details of Action
1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County, Ord. 91-1-102.
3. Providing drainage detention at the southwest corner of the property near Reagan Rd., or obtaining an off-site drainage easement at that location. Details to be worked out at the design plan stage of the subdivision.
4. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
5. Placing a note on the final plat that all lots will have access only to the internal street system.
6. Certification on the final plat by the applicant's surveyor that there is 300 feet of sight distance in both directions along Reagan Rd. at both entrances.
7. As a part of the final plat approval, record line of sight easements across the lots that are determined by the Knox County Department of Engineering and Public Works as needing sight distance easements for the curves in the interior streets .
8. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
9. Meeting all requirements of the approved use on review development plan.

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Reagan Landing

Fuad Reveiz


Case History