Subdivision

Concept Plan

3-SF-03-C

Recommended for approval
by the Planning Commission

APPROVE variance 1-3 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard
APPROVE the Concept Plan subject to 9 conditions


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Woodson Trail (Revised)
Lots
9 (Split)
Proposed Density
3.24 du/ac

Variances

1. Grade at intersection from 1% to 3% at sta. 0+30 of Road A.
2. Grade at intersection from 1% to 3% at sta. 1+00 of Road B.
3. Horizontal curve variance from 250 to 150' at sta. 5+50 of Road B.


Property Information

+
Location
South side of Woodson Dr., northeast of Spring Creek Rd.

Council District 1


Size
5.21 acres

Sector
South County

Currently on the Property
Vacant

Growth Plan
Urban Growth Area (Inside City Limits)

Case Notes

+
Staff Recommendation
APPROVE variance 1-3 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard

APPROVE the Concept Plan subject to 9 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville (City Ord. 0-280-90).
3. Compaction of fill areas to be done in accordance with the requirements of the Knoxville Engineering Dept..
4. Meeting all applicable requirements of the Knoxville Department of Engineering.
5. Place a note on the final plat that vehicular access is to be from the internal street system only.
6. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
7. Prior to issuance of any occupancy permits for any dwellings in Woodson Trail Subdivision, KUB must certify that adequate capacity exists in the sanitary sewer system to accommodate this development without contributing to the existing localized sewage overflow problem.
8. Meeting all requirements of the approved Use-on-Review development plan (12-D-02-UR).
9. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variance 1-3 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variance will not create a traffic hazard
APPROVE the Concept Plan subject to 9 conditions

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Woodson Trail (Revised)

R. W. Graf, Inc.


Case History