Subdivision

Concept Plan

12-SC-10-C

Approved as modified
by the Planning Commission

APPROVE variances 1 - 3 because the site's topography and narrowness restricts compliance with the regulations
APPROVE the concept plan subject to 13 conditions


See case notes below

Details

Request

Property Info

Case Notes

What's next?

Details of Action

+
(1 Deleteled at Commission.)
1. Provision of a 30' corner pavement radius on the north side of the entrance road at Francis Rd. per the requirements of the Knoxville Engineering Dept.
2. The drainage plan reflecting stormwater retention rather than detention
3. Obtaining any required off-site drainage easements prior to approval of the design plan if required
4. Meeting all other applicable requirements of the Knoxville Engineering Dept.
5. Participation in the KUB sewer capacity reservation program
6. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
7. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System in Knoxville
8. Provision of an appropriate subdivision name
9. Constructing the sidewalk within the development as shown on the plan. All sidewalk construction must be ADA compliant.
10. Providing a driveway from the proposed subdivision street to the adjoining property on the south side of the site (106GC005) an eliminating the existing driveway from that property to Francis Rd.
11. Creation of a property owners association for the purpose of maintaining the drainage facilities and other commonly held assets
12. Final approval of the rezoning of this site the Knoxville City Council with a density limit of 3.55 du/ ac or greater
13. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

Applicant Request

+
Subdivision
Worley Builders Francis Road
Lots
25 (Split)
Proposed Density
3.55 du/ac
Residential?
Yes - SF

Variances

1. Horizontal curve variance from 250' to 200' at sta. 9+75 of Road A
2. Broken back curve tangent length variance from 150' to 85' between sta 1+62.5 and sta 1+47.5 the proposed road
3. Variance of the southern property line radius at the entrance to the development from 25' to 0'


Property Information

+
Location
West side of Francis Rd., west of Francis Station Rd.

Council District 3


Size
7.08 acres

Sector
Northwest City

Currently on the Property
One detached dwelling and vacant land

Growth Plan
Urban Growth Area (Inside City Limits)

Case Notes

+
Staff Recommendation
APPROVE variances 1 & 2 because the site's topography and narrowness restricts compliance with the regulations
DENY variance 3 as recommended by the Knoxville Engineering Dept.

APPROVE the concept plan subject to 14 conditions

1. Provision of an appropriate property line corner radius on the south side of the entrance road at Francis Rd. per the requirements of the Knoxville Engineering Dept.
2. Provision of a 30' corner pavement radius on the north side of the entrance road at Francis Rd. per the requirements of the Knoxville Engineering Dept.
3. The drainage plan reflecting stormwater retention rather than detention
4. Obtaining any required off-site drainage easements prior to approval of the design plan if required
5. Meeting all other applicable requirements of the Knoxville Engineering Dept.
6. Participation in the KUB sewer capacity reservation program
7. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
8. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System in Knoxville
9. Provision of an appropriate subdivision name
10. Constructing the sidewalk within the development as shown on the plan. All sidewalk construction must be ADA compliant.
11. Providing a driveway from the proposed subdivision street to the adjoining property on the south side of the site (106GC005) an eliminating the existing driveway from that property to Francis Rd.
12. Creation of a property owners association for the purpose of maintaining the drainage facilities and other commonly held assets
13. Final approval of the rezoning of this site the Knoxville City Council with a density limit of 3.55 du/ ac or greater
14. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.
Disposition Summary
APPROVE variances 1 - 3 because the site's topography and narrowness restricts compliance with the regulations
APPROVE the concept plan subject to 13 conditions

Details of Action
(1 Deleteled at Commission.)
1. Provision of a 30' corner pavement radius on the north side of the entrance road at Francis Rd. per the requirements of the Knoxville Engineering Dept.
2. The drainage plan reflecting stormwater retention rather than detention
3. Obtaining any required off-site drainage easements prior to approval of the design plan if required
4. Meeting all other applicable requirements of the Knoxville Engineering Dept.
5. Participation in the KUB sewer capacity reservation program
6. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
7. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System in Knoxville
8. Provision of an appropriate subdivision name
9. Constructing the sidewalk within the development as shown on the plan. All sidewalk construction must be ADA compliant.
10. Providing a driveway from the proposed subdivision street to the adjoining property on the south side of the site (106GC005) an eliminating the existing driveway from that property to Francis Rd.
11. Creation of a property owners association for the purpose of maintaining the drainage facilities and other commonly held assets
12. Final approval of the rezoning of this site the Knoxville City Council with a density limit of 3.55 du/ ac or greater
13. A final plat application based on this concept plan will not be accepted for review by the MPC until certification of design plan approval has been submitted to the MPC staff.

What's next?

+
After the Planning Commission
Because of its location in the City, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Worley Builders Francis Road

Worley Builders, Inc.


Case History