Subdivision

Concept Plan

10-SE-05-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 & 2 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

APPROVE the concept plan subject to 11 conditions


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Fox Creek
Lots
143 (Split)
Proposed Density
1.87 du/ac
Residential?
Yes

Variances

1. Horizontal curve variance from 250' to 125' at sta. 14+75 of Road A.
2. Road grade variance on Road A from 12% to 14%


Property Information

+
Location
West side of Fox Rd., south of Pipkin Ln.

Council District 2


Size
76.51 acres

Sector
South County

Currently on the Property
Vacant land

Growth Plan
Urban Growth Area (Inside City Limits)

Case Notes

+
Staff Recommendation
APPROVE variances 1 & 2 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

APPROVE the concept plan subject to 11 conditions

1. Meeting all applicable requirements of the Knoxville Dept. of Engineering.
2. Certification on the final plat by the applicant's engineer that there is 300' of sight distance in both directions at the subdivision entrance looking on to Fox Road.
3. Compaction or fill areas to be done in accordance with the requirements of the Knoxville Dept. of Engineering.
4. Place a note on the final plat that all lots will have access from the internal street system only.
5. Meeting all requirements of the approved use on review development plan.
6. Connection to sanitary sewer and meeting any other relevant requirement of the Knox County Health Dept.
7. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville (Ord. 0-280-90).
8. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
9. Obtaining a street connection permit from the Tenn. Dept. of Transportation if required.
10. Place a note on the final plat that all structures will have to be located at least 50' from the top of the sinkholes (closed contour areas) on this site
11. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff.
Disposition Summary
APPROVE variances 1 & 2 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

APPROVE the concept plan subject to 11 conditions

What's next?

+
After the Planning Commission
Because of its location in the City, appeals will be heard by Knoxville City Council.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Fox Creek

S & E Properties


Case History