Subdivision

Concept Plan

1-SH-05-C

Recommended for approval
by the Planning Commission

APPROVE variances 1-6 because the existing site topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

APPROVE the concept plan subject to 9 conditions


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Arlington Ridge Subdivision
Lots
24 (Split)

Variances

1. Horizontal curve variances from 250' to 150' at sta 11+83, 20+53 & 27+62 of Road A
2. Horizontal curve variances from 250' to 200' at sta 67+36 & 69+10 and from 250' to 137.5' at sta67+36 of Road C
3. Reverse curve tangent variances from 50' to 23.38'at sta. 12+68, from 50' to 33.79' at sta 21+20 & from 50' to 33.57' at sta 28+50 of Road A
4. Vertical curve variances from 150 to 100' at sta 10+50, from 331.25' to 275' at sta 12+50 & from 387.5' to 325' at sta 24+25 of Road A
5. Vertical curve variances from 120' to 100' at sta 40+50 & from475' to 400' at sta 43+00 of Road B
6. Vertical curve variance from 269.5' to 250' at sta 71+00 of Road C


Property Information

+
Location
North side of Pleasant Gap Dr., northeast side of Andersonville Pk.

Commission District 8


Size
111.20 acres

Sector
North County

Currently on the Property
Vacant land

Growth Plan
Rural Area

Case Notes

+
Staff Recommendation
APPROVE variances 1-6 because the existing site topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

APPROVE the concept plan subject to 9 conditions

1. Meeting all applicable requirements of the Knox County Zoning Ordinance.
2. Meeting all applicable requirements of the Knox County Dept. of Engineering and Public Works.
3. Meeting all applicable requirements of the Knox County Health Dept.
4. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knox County (Ord. 91-1-102).
5. Place a note on the final plat that access to all lots will only be the internal road system.
6. Certification on the final plat by the applicant's engineer that there is 300' of sight distance in both directions at the entrance to this development looking onto Pleasant Gap Rd.
7. Place a note on the concept plan that all of the grades at each intersection that are less than 3% have been reviewed and approved by the Knox County Dept. of engineering and Public Works.
8. Prior to final plat approval establish a homeowners association for the purpose of assessing and collecting fees for the maintenance of the joint permanent easements and any other commonly held assets such as the common areas shown on the concept plan and for the payment of the property taxes on these commonly held assets.
9. A final plat based on this concept plan will not be accepted for review by MPC until certification
Disposition Summary
APPROVE variances 1-6 because the existing site topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard

APPROVE the concept plan subject to 9 conditions