Subdivision

Concept Plan

1-SC-15-C

Recommended for approval
by the Planning Commission

APPROVE variances 1 - 7 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
DENY variance # 8

APPROVE the Concept Plan subject to 13 conditions:


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Arcadia
Lots
30 (Split)
Proposed Density
.34 du/ac
Residential?
Yes - SF

Variances

1. Horizontal curve variance from 250' to 200' at sta 9+00 and 14+25 of Road A
2. Horizontal curve variance from 250' to 150' at sta 7+25 and 10+75 of Road B
3 Horizontal curve variance from 250' to 130' at sta 13+25 of Road B
4. Variance of broken back curve tangent length from 150' to 109' at sta 10+00 to sta 11+09 of Road A
5. Variance of broken back curve tangent length from 150' to 81' at sta 30+89 to sta 31+70 of Road A
6. Variance of Roadway grade from 12% to 15% from sta 7+05 to sta 13+75 on Road B
7. Variance of joint permanent easement pavement widths to as shown
8. Horizontal curve variance from 100' to 50' at sta 1+00 of Roads E and F


Property Information

+
Location
Southwest end of Chandler Ln., southeast of S. Northshore Dr.

Commission District 5


Size
89.35 acres

Sector
Southwest County

Currently on the Property
Farm land with single family dwellings and out buildings

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variances 1 - 7 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
DENY variance # 8

APPROVE the Concept Plan subject to 13 conditions:

1. Connection to sanitary sewer and meeting all other applicable requirements of the Knox County Health Dept.
2. Widen Chandler Ln, from the subdivision entrance to S. Northshore Dr. to a minimum width of 20' with shoulders as required by the Knox County Dept. of Engineering and Public Works
3. Installation of 3 actuated flashers at the S. Northshore/Chandler/Blue Grass intersection per an agreement with Knox County
4. Provision of curbs on all JPEs as may be required by the Knox County Dept. of Engineering and Public Works
5. Provide an AASHTO approved turn around at the end of all JPEs
6. Prior to final plat approval, establish a homeowners association for the purpose of maintaining all of the JPEs, storm drainage facilities and all other commonly held assets
7. Provision of street names which are consistent with the Uniform Street Naming and Addressing System in Knox County (Ord 91-1-102)
8. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation, Tenn. Valley Authority and the Army Corp of Engineers
Disposition Summary
APPROVE variances 1 - 7 because the site's topography restricts compliance with the Subdivision Regulations, and the proposed variances will not create a traffic hazard.
DENY variance # 8

APPROVE the Concept Plan subject to 13 conditions:

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Arcadia

Beacon Park, LLC


Case History