Subdivision

Concept Plan

1-SB-04-C

Recommended for approval
by the Planning Commission

APPROVE variances 1-5 because the site's topography restricts compliance with the Subdivision Regulations.
APPROVE the concept plan subject to 9 conditions


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Westmoreland Estates
Lots
22 (Split)

Variances

1. Horizontal curve variance from 250' to 125' at sta. 0+75 of Road A.
2. Horizontal curve variance from 250' to 100' at sta. 2+50 of Road A.
3. Horizontal curve variance from 250' to 100' at sta. 8+50 of Road A.
4. Grade at intersection from 1% to 2% at Lawford Road and Road A.
5. Grade at intersection from 1% to 2% at Road A and Road B.


Property Information

+
Location
East side of Lawford Rd., north of Scottswood Circle

Council District 2


Size
13.28 acres

Sector
West City

Currently on the Property
Vacant land

Growth Plan
Urban Growth Area (Inside City Limits)

Case Notes

+
Staff Recommendation
APPROVE variances 1-5 because the site's topography restricts compliance with the Subdivision Regulations.

APPROVE the concept plan subject to 9 conditions

1. Meeting all applicable requirements of the Knoxville Zoning Ordinance.
2. Meeting all requirements of the Knoxville Dept. of Engineering.
3. Connection to sanitary sewer and meeting all other applicable requirements of the Knox County Health Dept.
4. Provision of street names which are consistent with the Uniform Street Naming and Addressing System within Knoxville, O-280-90.
5. Delineating on the plan the 500 year and 100 year flood boundaries, the floodway fringe and the no-fill areas.
6. Establishing Minimum Floor Elevations (MFE) for lots 14,15,19,20 and 21.
7. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation.
8. Installing fencing and landscaping between the railroad tracks and the rear of lots 3 through10. It is to be comparable to the existing fencing and landscaping that was done as part of the previous units of this subdivision.
9. A final plat based on this concept plan will not be accepted for review by MPC until certification of design plan has been submitted to MPC staff.
Disposition Summary
APPROVE variances 1-5 because the site's topography restricts compliance with the Subdivision Regulations.
APPROVE the concept plan subject to 9 conditions

What's next?

+
After the Planning Commission
Because of its location in the City, appeals will be heard by City Council.
City Council
March 2, 2004
May 11, 2004
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Westmoreland Estates

Wide Horizon Development


Case History