Subdivision

Concept Plan

4-SA-19-C

Recommended for approval
by the Planning Commission

APPROVE variances 1-5 because the site's topography restricts compliance with the Subdivision Regulations and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 7 conditions


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Broady Glen
Lots
52 (Split)
Proposed Density
2.0849 du/ac
Residential?
Yes - SF

Variances

Variances requiring Planning Commission approval:

1. Horizontal curve variance at STA 9+71.84, from 250' to 120'.
2. Horizontal curve variance at STA 12+76.31, from 250' to 120'.
3. Broken back curve tangent variance between STA 11+93.21 and STA 12+76.31, from 150' to 83.1'.
4. Reduction of the vertical curve K-value between STA 0+12.43 and STA 1+19.33, from 25 to 20.
5. Reduction of the vertical curve K-value between STA 1+34.23 and STA 2+71.70, from 25 to 20.

Waiver approved by Knox County Department of Engineering and Public Works:

1. Intersection grade waiver from 1% to up to 2.9% as identified on the concept plan


Property Information

+
Location
1921 Marietta Church Rd

West side of Marietta Church Road at Ricketts Lane

Commission District 6
Census Tract 59.05


Size
24.94 acres

Sector
Northwest County

Currently on the Property
Residence and vacant land

Growth Plan
Rural Area

Case Notes

+
Staff Recommendation
APPROVE variances 1-5 because the site's topography restricts compliance with the Subdivision Regulations and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 7 conditions

1. Connection to sanitary sewer and meeting any other relevant requirements of the Knox County Health Department.
2. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System within Knox County (Ord 91-1-102).
3. Meeting all applicable requirements of the Knox County Department of Engineering and Public Works.
4. Meeting all applicable requirements and obtaining all required permits from the Tennessee Department of Environment and Conservation for crossing the blueline stream on the property.
5. On the final plat, including the line of sight easement across Lots 40 and 41 as identified on the concept plan (200' minimum distance) and as required by the Knox County Department of Engineering and Public Works.
6. Prior to certification of the final plat for the subdivision, establishing a property owners association that will be responsible for the maintenance of the common areas, drainage system and any recreational amenities.
7. Submitting to Planning staff prior to final plat review by the Planning Commission, the certification of design plan approval form as required by the Knoxville-Knox County Subdivision Regulations.
Disposition Summary
APPROVE variances 1-5 because the site's topography restricts compliance with the Subdivision Regulations and the proposed variances will not create a traffic hazard.

APPROVE the Concept Plan subject to 7 conditions

What's next?

+
After the Planning Commission
Because of its location in the County, appeals will be heard by Knox County Chancery Court.
Appeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Broady Glen

Urban Engineering, Inc.


Case History