Subdivision

Concept Plan

4-SA-06-C

Recommended for approval
by the Planning Commission

APPROVE variance 1 because of sites shape and topography and the proposed variance will not create a traffic hazard

APPROVE the Concept Plan subject to 13 conditions


See case notes below

Request

Property Info

Case Notes

What's next?

Applicant Request

+
Subdivision
Willow Brook
Lots
22
Residential?
Yes - SF

Variances

1. Vertical curve variance from 187.5' to 125' at sta 10+75 of Road A.


Property Information

+
Location
Southeast side of W. Beaver Creek Dr, southwest of Fairlane Dr

Commission District 6
Census Tract 61.01


Size
12.05 acres

Sector
North County

Currently on the Property
Vacant land

Growth Plan
Planned Growth Area

Case Notes

+
Staff Recommendation
APPROVE variance 1 because of sites shape and topography and the proposed variance will not create a traffic hazard

APPROVE the Concept Plan subject to 13 conditions

1. Connection to sanitary sewer and meeting all other applicable requirements of the Knox County Health Dept.
2. Provision of a street name which is consistent with the Uniform Street Naming and Addressing System within Knox County (ORD. 91-1-102).
3. Meeting all applicable requirements and obtaining all required permits from the Tenn. Dept. of Environment and Conservation
4. Provision of stormwater detention facilities as required by the Knox County Dept. of Engineering and Public Works
5. Provision of the required dedication of 35' from the center line along the site's frontage on W. Beaver Creek Dr.
6. Provision of the required 25' radius at the property line and at the edge of pavement at the proposed intersection of Road A and W. Beaver Creek Dr.
7. Provision of the required 75' transition radius in the proposed cul de sac
8. Establishing minimum floor elevations for lots 17 - 24 as required by the Knox County Dept. of Engineering and Public Works
9. Review and approval by MPC staff of the proposed relocation of the existing power lines to insure that each proposed lot will have a suitable building site
10. Meeting all other applicable requirements of the Knox County Dept. of Engineering and Public Works
11. Meeting all applicable requirements of the Knox County Zoning Ordinance
12. Certification on the final plat by the applicant's engineer that there is 450' of sight distance in both directions on W. Beaver Creek Dr. at the entrance road and at the proposed driveway to lot 24
13. A final plat application based on this concept plan will not be accepted for review by MPC until a certification of design plan has been submitted to the MPC Staff.
Disposition Summary
APPROVE variance 1 because of sites shape and topography and the proposed variance will not create a traffic hazard

APPROVE the Concept Plan subject to 13 conditions

What's next?

+
After the Planning CommissionAppeals of Concept Plans and Final Plats are filed with Chancery CourtThe Process
Applicant

Willow Brook

Legacy Builders


Case History